Produk Kami

MC Control ( XHHW-2 )

TANTANGAN ANDA ADALAH PROGRESS KAMI

Identification of Cores:

Based on color coding per ICEA method 1, table E-2 ( for detail see table )

Other colours are available on request

 

Construction:

  1. Bare, Annealed, Stranded Copper Conductor
  2. Extruded XLPE Insulation
  3. Polyprophylene Yarn Filler ( as necessary )
  4. Polyester Tape Binder
  5. Aluminium Welded Corrugated Armour
  6. Extruded PVC Outer Sheath ( Black Colour )

 

Construction:

Item Number No. of Core Size Thickness Overall Diameter Core Overall Diameter Armour Approx Overall Diameter Cable Approx Net. Weight Standard Length
Insulation Outer Sheath
AWG kcmil / mm2 mm mm mm mm mm Kg/Km m
ANXMY000020014ME 2 14 / 2.08 0,76 1,27 7,1 13,9 16,6 289 1000
ANXMY000030014ME 3 7,7 14,5 17,2 322 1000
ANXMY000040014ME 4 8,5 15,3 18,1 362 1000
ANXMY000050014ME 5 9,5 16,3 19,1 406 1000
ANXMY000070014ME 7 10,6 17,4 20,1 470 1000
ANXMY000090014ME 9 14,0 20,8 23,5 602 1000
ANXMY000120014ME 12 14,5 21,3 24,1 676 1000
ANXMY000190014ME 19 17,5 24,3 27,0 901 1000
ANXMY000370014ME 37 24,4 33,8 36,5 1598 1000
ANXMY000020012ME 2 12 / 3.31 0,76 1,27 8,1 14,9 17,6 333 1000
ANXMY000030012ME 3 8,7 15,5 18,2 378 1000
ANXMY000040012ME 4 9,7 16,5 19,2 433 1000
ANXMY000050012ME 5 10,8 17,6 20,4 492 1000
ANXMY000070012ME 7 12,0 18,8 21,5 583 1000
ANXMY000090012ME 9 15,9 22,7 25,5 754 1000
ANXMY000120012ME 12 16,5 23,3 26,1 864 1000
ANXMY000190012ME 19 19,9 26,7 29,4 1182 1000
ANXMY000370012ME 37 27,7 37,1 40,4 2177 1000
ANXMY000020010ME 2 10 / 5.26 0,76 1,27 9,3 16,1 18,8 395 1000
ANXMY000030010ME 3 10,0 16,8 19,5 460 1000
ANXMY000040010ME 4 11,1 17,9 20,7 536 1000
ANXMY000050010ME 5 12,4 19,2 22,0 618 1000
ANXMY000070010ME 7 13,8 20,6 23,3 750 1000
ANXMY000090010ME 9 18,3 25,1 27,9 979 1000
ANXMY000100010ME 12 19,0 25,8 28,6 1143 1000

 

 

CHARACTERISTICS:

Item Number No. of Core Size Resistance at 20o C AC Voltage Test
Max DC Conductor Min. Insulation
    AWG kcmil / mm2 Ohm / Km M.Ohm.Km kA / 5 mins
ANXMY000020014ME 2 14 / 2.08 8,463 1000 3,5
ANXMY000030014ME 3 8,463 1000 3,5
ANXMY000040014ME 4 8,463 1000 3,5
ANXMY000050014ME 5 8,463 1000 3,5
ANXMY000070014ME 7 8,463 1000 3,5
ANXMY000090014ME 9 8,463 1000 3,5
ANXMY000120014ME 12 8,463 1000 3,5
ANXMY000190014ME 19 8,463 1000 3,5
ANXMY000370014ME 37 8,463 1000 3,5
ANXMY000020012ME 2 12 / 3.31 5,342 1000 3,5
ANXMY000030012ME 3 5,342 1000 3,5
ANXMY000040012ME 4 5,342 1000 3,5
ANXMY000050012ME 5 5,342 1000 3,5
ANXMY000070012ME 7 5,342 1000 3,5
ANXMY000090012ME 9 5,342 1000 3,5
ANXMY000120012ME 12 5,342 1000 3,5
ANXMY000190012ME 19 5,342 1000 3,5
ANXMY000370012ME 37 5,342 1000 3,5
ANXMY000020010ME 2 10 / 5.26 3,346 1000 3,5
ANXMY000030010ME 3 3,346 1000 3,5
ANXMY000040010ME 4 3,346 1000 3,5
ANXMY000050010ME 5 3,346 1000 3,5
ANXMY000070010ME 7 3,346 1000 3,5
ANXMY000090010ME 9 3,346 1000 3,5
ANXMY000100010ME 12 3,346 1000 3,5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONDUCTOR COLOR CODING SEQUENCE PER ICEA METHOD 1 TABLE E-2
Note: Color code repeats after 36 conductors

 

 

Conductor Number Base Color Stripe Color Conductor Number Base Color Stripe Color
1 Black --- 19 Orange Blue
2 Red --- 20 Yellow Blue
3 Blue --- 21 Brown Blue
4 Orange --- 22 Black Orange
5 Yellow --- 23 Red Orange
6 Brown --- 24 Blue Orange
7 Red Black 25 Yellow Orange
8 Blue Black 26 Brown Orange
9 Orange Black 27 Black Yellow
10 Yellow Black 28 Red Yellow
11 Brown Black 29 Blue Yellow
12 Black Red 30 Orange Yellow
13 Blue Red 31 Brown Yellow
14 Orange Red 32 Black Brown
15 Yellow Red 33 Red Brown
16 Brown Red 34 Blue Brown
17 Black Blue 35 Orange Brown
18 Red Blue 36 Yellow Brown

 

Symbol : MC Control ( XHHW-2 )
Copper Conductor, XLPE Insulation with Aluminium Welded Corrugated Armoured and PVC Sheath
Applicable Standard : Type of Cable: MC-HL CONTROL or CU/XLPE/MC/PVC
Rated Voltage: 0.6/1kV
Specification : IEC 60502-1
ICEA S-73-532/NEMA WC57
ASTM B-8
UL 44

Other Specification are available on request

Application : Indoor and outdoor ( wet or dry location )
Branch circuit for power,lighting, control and signaling
As aerial cable on a messenger
Installation direct burial
Installation cable tray
Approved for classes I,II and III Division 1 and 2, Class 1, Zones 1 and 2
Belum ada data
Belum ada data

Untuk mengunduh detail produk anda harus masuk atau jika anda belum akun silahkan mendaftar terlebih dahulu, Klik disini untuk mendaftar